Power Inverter Safety Tips

While having best power inverter can help you, to really make the most of it, it needs to be installed and utilized appropriately. Make sure you always look into the installation and operating instructions very carefully before installing and using it. Furthermore, incorrect use can lead to hazardous conditions. 110 Volts of current can be fatal. Improper use of a power inverter can lead to property damage, personal injury, or loss of life. Here, we list quite a few to watch for. However, this is definitely not a complete list of issues you should be thinking about when install or use power inverter. Please always read and follow carefully the instructions in the owner’s manual provided with every inverter for crucial safety considerations and precautions. If you are still not sure after reading the inverter manual, please seek advice from professionals.

General Precautions

1. Under no circumstances install the inverter inside a boat’s engine compartment in which gas and battery fumes exist.
2. Don’t operate the inverter if it has been dropped or broken in any way.
3. Do not open up the inverter; it has no user serviceable parts. Trying to service unit could potentially cause electrical shock. Internal components stay charged after all power is turned off.
4. Don’t expose the inverter to rain, snow, water or spray.
5. Do not block the venting openings.
6. Don’t install the inverter within zero-clearance compartment.

Guideline for proper installationPower Inverter Safety Tips

If you’re building a permanent AC connection to the inverter, ensure that the AC wiring steps are carried out before any DC wiring is performed. (DC hook-up stimulates internal components, whatever the position of the On/Off Switch). Working on AC connections in this particular circumstance could lead to an electric shock.

Don’t work on AC wiring when it’s attached to the inverter (even when it is turned off) except if the DC power source is physically disconnected from your inverter. Also, don’t work on AC wiring if it’s linked to another AC power source like a generator or the utility line. You might notice a spark when creating the connection simply because current can move to charge the capacitors inside the inverter.

Never makes this connection in the existence of flammable fumes. Explosion or fire may result. Extensively ventilate the battery compartment prior to making this connection. We suggest a primary fuse in the battery’s positive cable to safeguard against DC wiring short circuits. The fuse needs to be as near to the battery as possible. The actual fuse ampere rating needs to be sized to allow for operation of all your DC powered equipment. You should never short circuit the battery with any metallic object.

Electric installations should meet local and national wiring codes, and ought to be performed by a professional electrician.
Loose connectors lead to excessive voltage drop and could cause over heated wires and melted insulation. To prevent fire, do not cover or obstruct ventilation openings. Don’t install inverter in a zero-clearance compartment. Overheating may result.

Power inverters consist of components which often generate electrical arcs or sparks. To avoid fire or explosion, don’t install the inverter in areas or compartments that contains batteries or flammable materials or in locations which involve ignition-protected equipment. Put the inverter on the reasonably flat working surface, either horizontally or vertically.

The inverter shouldn’t be placed in the engine compartment, because of possible water oil or acid contamination, and excessive heat underneath the hood, along with potential danger from gasoline fumes and also the spark that an inverter can often produce.

It is best to run battery cables to the dry, cool inverter mounting location. Keep your inverter dry. Don’t expose it to rain or moisture.

Avoid putting the inverter on or near heating vents, radiators or other resources for heat. Never put the inverter in sunlight. Great air temperatures are between 50° and 80° F. As a way to appropriately spread heat generated whilst the inverter is at operation, keep it well ventilated. When it’s in use, maintains several inches of clearance round the top and sides from the inverter.

While we try out best to make sure all the information is correct. There will be typos inevitably. If there is confusion, please always refer to the user manual of your power inverter reviews. Furthermore, you should always get the help from the professionals.